background image

Pulsar Plus Controller Family

Issue 7 December 2011

31

Connect to the Controller

Step

Action

2

One-Wire Battery Peripheral Connector

J2 is a standard shielded RJ-45 receptacle provided for making connections to “1-Wire” devices
such as QS873 VT-Probes (up to 16) and ES771A Remote Mid-string Voltage Monitors (up to six).
Standard cable assemblies have been designed and must be used for applications involving the
QS873 VT-Probes or ES771 Remote Mid-string Voltage monitors. These cables provide simple
plug-n-play from the controller to a QS873A probe, from the controller to an ES771A, and
between QS873A probes and ES771 modules. Consult the section on “1-Wire” peripherals for
further information. Following are the present pin assignments for J2.

Pin #

Signal
Name

Description

1

reserved

2

reserved

3

SIG_RTN Protected signal return for 1-wire

4

reserved

5

1-Wire

1-wire communication signal

6

+5V

Protected +5V Power utilized by ES771 modules

7

reserved

8

reserved


Note: J2 does not contain the RS485 rectifier control bus

3

Auxiliary Input Connector

J3 is 10-pin right angle header that provides a separate connection for auxiliary inputs. Standard
color coded cable assemblies are available. Part numbers for the 50’ and 150’ 24AWG input
cables are CC848817651 and CC848817668, respectively. Contact technical field support for
additional cable options or needs. Utilize the appropriate cable to obtain the desired connections
to the inputs shown below.