Pulsar Plus Controller Family

Issue 7 December 2011

73

Table 17 Enabled/Disabled Info Status

All Load Monitored

Shows if the All Loads Monitored feature is Enabled or Disabled. This assumes
that every load distribution is being monitored so the sum of the load currents
can be used to equal the total load of the system.

Disconnects

Shows if the LVBD (Low Voltage Battery Disconnect) and LVLD1-3 (Low Voltage
Load Disconnects) features are Enabled or Disabled.

Conv Disconnect

Shows if the low voltage Converter Disconnect feature is Enabled or Disabled.

Conv Remote Off

Shows if the Remote Converter Off – Individual Remote Converter Standby
feature is Enabled or Disabled.

Conv Redundancy

Shows if the Converter redundancy feature is Enabled or Disabled.

Remote Rect Off

Shows if the Remote Rectifier Off – Individual Remote Rectifier Standby is
Enabled or Disabled.

Rectifier Sequencing Shows if the Rectifier Sequencing is Enabled or Disabled.
Local Write

Whether or not the system can be configured through the local port.

Modem Write

Whether or not the system can be configured through the modem port.

Network Write

Whether or not the system can be configured through the network.

Usernames

Whether or not usernames and password identification have been enabled

Network Settings

This section of the menu displays the settings of the Network parameters for the two Ports. Controllers
presently only utilizes Port 1. Port 2 is reserved for a second Ethernet port in the future.

Table 18 Network Settings Status

Host Name

Network name assigned and configured for the controller since it acts as a
repository for data and services such as e-mail, FTP, HTTP, etc that are accessed
remotely by other equipment or users on the network.

IP Address

*

Internet Protocol address assigned to the controller that identifies the unit on
the network. The format for the IP address field is a 32-bit numeric address
written as four numbers separated by periods (ddd.ddd.ddd.ddd). Each
number, ddd, can be 0 to 255. In the server mode, 192.168.2.1 is used to access
the controller.

Subnet Mask

*

Internal network address assigned for identifying an internal network mask that
the controller has been assigned to by a network administrator. The mask
selectively includes or excludes certain equipment on a Host. The format for the
Subnet Mask field is a 32-bit numeric address written as four numbers
separated by periods (ddd.ddd.ddd.ddd). Each number, ddd, can be 0 to 255.

DHCP

This field indicates the operational mode of the integrated Ethernet port. The
port can be operating as a DHCP Client, Static Client, or a DHCP Server. DHCP
Server is the default mode of operation for Infinity NE Craft port and Static is
the default for the LAN port.

Gateway

*

This address is for the address of the Gateway or node on the network that will
serve as the entrance to another network for the controller. This address is the
address of the equipment or computer that routes the traffic from and to the
controller to the outside network. It is generally the proxy server. The format
for the Gateway address field is a 32-bit numeric address written as four