Configuring qinq, Overview, Background and benefits – H3C Technologies H3C S12500 Series Switches User Manual

Page 151: How qinq works

Advertising
background image

138

Configuring QinQ

Throughout this document, customer network VLANs (CVLANs), also called inner VLANs, refer to the

VLANs that a customer uses on the private network; and service provider network VLANs (SVLANs), also

called outer VLANs, refer to the VLANs that a service provider uses to carry VLAN tagged traffic for
customers.

Overview

QinQ stands for 802.1Q in 802.1Q. QinQ is a flexible, easy-to-implement Layer 2 VPN technology

based on IEEE 802.1Q. QinQ enables the edge device on a service provider network to insert an outer
VLAN tag in the Ethernet frames from customer networks, so that the Ethernet frames travel across the

service provider network (public network) with double VLAN tags. QinQ enables a service provider to

use a single SVLAN to serve customers who have multiple CVLANs.

Background and benefits

The IEEE 802.1Q VLAN tag uses 12 bits for VLAN IDs. A device supports a maximum of 4094 VLANs.

This is far from enough for isolating users in actual networks, especially in metropolitan area networks

(MANs).
By tagging tagged frames, QinQ expands the available VLAN space from 4094 to 4094 × 4094. QinQ

delivers the following benefits:

Releases the stress on the SVLAN resource.

Enables customers to plan their CVLANs without conflicting with SVLANs.

Provides an easy-to-implement Layer 2 VPN solution for small-sized MANs or intranets.

Allows the customers to keep their VLAN assignment schemes unchanged when the service provider
upgrades the service provider network.

How QinQ works

The devices in the public network forward a frame only according to its outer VLAN tag and learn its

source MAC address into the MAC address table of the outer VLAN. The inner VLAN tag of the frame is

transmitted as the payload.