The output shows that no loop is detected on GigabitEthernet 4/0/1 and GigabitEthernet 4/0/2. The

reason is that the loopback detection action is set to shutdown, in which case, the two ports are
automatically shut down when a loop occurs on them. The shutdown action removes the loop. Use the

display interface command to display the status information of GigabitEthernet 4/0/1 and

GigabitEthernet 4/0/2 on Device A:
# Display the status information of GigabitEthernet 4/0/1 on Device A.

[DeviceA] display interface gigabitethernet 4/0/1

GigabitEthernet 4/0/1 current state: DOWN ( Loopback detection-protected )

...

# Display the status information of GigabitEthernet 4/0/2 on Device A.

[DeviceA] display interface gigabitethernet 4/0/2

GigabitEthernet 4/0/2 current state: DOWN ( Loopback detection-protected )

...

The output above shows that GigabitEthernet 4/0/1 and GigabitEthernet 4/0/2 have already been
shut down by the loopback detection module.