Step Command

Remarks

5.

Configure the PVID of the
hybrid port.

port hybrid pvid vlan vlan-id

Optional.
By default, the PVID of a hybrid

port is the ID of the VLAN to which
the port belongs when its link type

is access.
After configuring the PVID for a

hybrid port, you must use the port
hybrid vlan command to configure

the hybrid port to allow packets

from the PVID to pass through, so

that the egress port can forward
packets from the PVID.

Port-based VLAN configuration example

Network requirements

As shown in

Figure 6

, Host A and Host C belong to Department A, and access the enterprise network

through different switches. Host B and Host D belong to Department B. They also access the enterprise

network through different switches.
To ensure communication security and prevent broadcast storms, VLANs are configured in the enterprise
network to isolate Layer 2 traffic of different departments. VLAN 100 is assigned to Department A, and

VLAN 200 is assigned to Department B.
Make sure hosts within the same VLAN can communicate with each other, in other words, Host A can

communicate with Host C, and Host B can communicate with Host D.

Figure 6 Network diagram

Configuration procedure

1.

Configure Device A:
# Create VLAN 100, and assign port GigabitEthernet 3/0/1 to VLAN 100.

<DeviceA> system-view

[DeviceA] vlan 100

[DeviceA-vlan100] port GigabitEthernet 3/0/1

[DeviceA-vlan100] quit

# Create VLAN 200, and assign port GigabitEthernet 3/0/2 to VLAN 200.

[DeviceA] vlan 200

[DeviceA-vlan200] port GigabitEthernet 3/0/2

[DeviceA-vlan200] quit