H3C Technologies H3C S7500E Series Switches User Manual

Page 124

Advertising
background image

5-17

To do...

Use the command...

Remarks

Configure the IGMP

last-member query interval

last-member-query-interval

interval

Optional

1 second by default

Configure the other querier

present interval

timer other-querier-present

interval

Optional

By default, the other querier

present interval is [ IGMP

general query interval ] × [ IGMP

robustness variable ] +

[ maximum response time for

IGMP general queries ] / 2.

Configuring IGMP query and response parameters on an interface

Follow these steps to configure IGMP query and response parameters on an interface:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter interface view

interface interface-type

interface-number

Configure the IGMP querier’s

robustness variable

igmp robust-count

robust-value

Optional

2 by default

Configure the startup query

interval

igmp startup-query-interval

interval

Optional

By default, the startup query

interval is 1/4 of the “IGMP

general query interval”.

Configure the startup query

count

igmp startup-query-count

value

Optional

By default, the startup query

count is set to the IGMP

querier’s robustness variable.

Configure the IGMP general

query interval

igmp timer query interval

Optional

60 seconds by default

Configure the maximum

response time for IGMP general

queries

igmp max-response-time

interval

Optional

10 seconds by default

Configure the IGMP last

member query interval

igmp

last-member-query-interval

interval

Optional

1 second by default

Advertising