H3C Technologies H3C S7500E Series Switches User Manual

Page 192

Advertising
background image

6-55

# On Switch C, configure VLAN-interface 103 and VLAN-interface 106 to be the boundary of

admin-scope zone 2.

<SwitchC> system-view

[SwitchC] interface vlan-interface 103

[SwitchC-Vlan-interface103] multicast boundary 239.0.0.0 8

[SwitchC-Vlan-interface103] quit

[SwitchC] interface vlan-interface 106

[SwitchC-Vlan-interface106] multicast boundary 239.0.0.0 8

[SwitchC-Vlan-interface106] quit

# On Switch D, configure VLAN-interface 107 to be the boundary of admin-scope zone 2.

<SwitchD> system-view

[SwitchD] interface vlan-interface 107

[SwitchD-Vlan-interface107] multicast boundary 239.0.0.0 8

[SwitchD-Vlan-interface107] quit

4) Configure C-BSRs and C-RPs

# On Switch B, configure the service scope of RP advertisements and configure VLAN-interface

101 as a C-BSR and C-RP of admin-scope zone 1.

[SwitchB] acl number 2001

[SwitchB-acl-basic-2001] rule permit source 239.0.0.0 0.255.255.255

[SwitchB-acl-basic-2001] quit

[SwitchB] pim

[SwitchB-pim] c-bsr group 239.0.0.0 8

[SwitchB-pim] c-bsr vlan-interface 101

[SwitchB-pim] c-rp vlan-interface 101 group-policy 2001

[SwitchB-pim] quit

# On Switch D, configure the service scope of RP advertisements and configure VLAN-interface

104 as a C-BSR and C-RP of admin-scope zone 2.

[SwitchD] acl number 2001

[SwitchD-acl-basic-2001] rule permit source 239.0.0.0 0.255.255.255

[SwitchD-acl-basic-2001] quit

[SwitchD] pim

[SwitchD-pim] c-bsr group 239.0.0.0 8

[SwitchD-pim] c-bsr vlan-interface 104

[SwitchD-pim] c-rp vlan-interface 104 group-policy 2001

[SwitchD-pim] quit

# On Switch F, configure VLAN-interface 109 as a C-BSR and C-RP in the global scope zone.

<SwitchF> system-view

[SwitchF] pim

[SwitchF-pim] c-bsr global

[SwitchF-pim] c-bsr vlan-interface 109

[SwitchF-pim] c-rp vlan-interface 109

[SwitchF-pim] quit

5) Verify

the

configuration

To view the BSR election information and the C-RP information on a switch, use the display

pim bsr-info command. For example:

# View the BSR information and the locally configured C-RP information on Switch B.

[SwitchB] display pim bsr-info

Elected BSR Address: 10.110.9.1

Advertising