Network diagram, Configuration procedure – H3C Technologies H3C S7500E Series Switches User Manual

Page 196

Advertising
background image

6-59

Network diagram

Figure 6-13 Network diagram for PIM-SSM configuration

Ether

net

Ether

net

E

thernet

N1

N2

Vl

an-

in

t101

Vlan-

int10

1

Device Interface IP address

Device

Interface IP

address

Switch A

Vlan-int100

10.110.1.1/24

Switch D

Vlan-int300

10.110.5.1/24

Vlan-int101

192.168.1.1/24

Vlan-int101

192.168.1.2/24

Vlan-int102

192.168.9.1/24

Vlan-int105

192.168.4.2/24

Switch B

Vlan-int200

10.110.2.1/24

Switch E

Vlan-int104

192.168.3.2/24

Vlan-int103

192.168.2.1/24

Vlan-int103

192.168.2.2/24

Switch C

Vlan-int200

10.110.2.2/24

Vlan-int102

192.168.9.2/24

Vlan-int104

192.168.3.1/24

Vlan-int105

192.168.4.1/24

Configuration procedure

1) Configure IP addresses and unicast routing

Configure the IP address and subnet mask for each interface as per

Figure 6-13

. Detailed

configuration steps are omitted here.

Configure the OSPF protocol for interoperation among the switches in the PIM-SM domain.

Ensure the network-layer interoperation in the PIM-SM domain and enable dynamic update of

routing information among the switches through a unicast routing protocol. Detailed

configuration steps are omitted here.

2) Enable IP multicast routing, and enable PIM-SM and IGMP

# Enable IP multicast routing on Switch A, enable PIM-SM on each interface, and run IGMPv3

on VLAN-interface 100, which connects Switch A to the stub network.

<SwitchA> system-view

[SwitchA] multicast routing-enable

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] igmp enable

[SwitchA-Vlan-interface100] igmp version 3