Network requirements, Configuration procedure – H3C Technologies H3C S5560 Series Switches User Manual
Page 195
161
•
The trunk promiscuous port GigabitEthernet 1/0/1 is a tagged member of primary VLAN 5 and
secondary VLANs 2 and 3.
•
The host port GigabitEthernet 1/0/2 is an untagged member of primary VLAN 5 and secondary
VLAN 2.
•
The host port GigabitEthernet 1/0/3 is an untagged member of primary VLAN 5 and secondary
VLAN 3.
Trunk promiscuous and trunk secondary port configuration
example
Network requirements
As shown in
, configure the private VLAN feature to meet the following requirements:
•
VLANs 10 and 20 are primary VLANs on Device A. The uplink port GigabitEthernet 1/0/5 on
Device A permits the packets from VLANs 10 and 20 to pass through tagged.
•
VLAN 11, VLAN 12, VLAN 21, and VLAN 22 are secondary VLANs on Device A.
{
The downlink port GigabitEthernet 1/0/2 permits the packets from VLAN 11 and VLAN 21 to
pass through tagged.
{
The downlink port GigabitEthernet 1/0/1 permits VLAN 22.
{
The downlink port GigabitEthernet 1/0/3 permits VLAN 12.
•
Secondary VLANs 11 and 12 are associated with primary VLAN 10.
•
Secondary VLANs 21 and 22 are associated with primary VLAN 20.
Figure 49 Network diagram
Configuration procedure
1.
Configure Device A: