246

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2/Layer 3 Ethernet
interface view, management

Ethernet interface view, or
Layer 2/Layer 3 aggregate

interface view.

interface interface-type
interface-number

N/A

3.

Allow LLDP to advertise the

management address in LLDP
frames and configure the

advertised management

address.

In Layer 2/Layer 3 Ethernet

interface view or management
Ethernet interface view:

lldp [ agent { nearest-customer

| nearest-nontpmr } ]
tlv-enable basic-tlv

management-address-tlv

[ ip-address ]

In Layer 2/Layer 3 aggregate

interface view:

lldp agent { nearest-customer

| nearest-nontpmr } tlv-enable
basic-tlv

management-address-tlv

[ ip-address ]

By default:

Nearest bridge agents and

nearest customer bridge agents

can advertise the management

address in LLDP frames.

Nearest non-TPMR bridge

agents cannot advertise the

management address in LLDP
frames.

4.

Configure the encoding
format of the management

address as string.

In Layer 2/Layer 3 Ethernet
interface view or management

Ethernet interface view:

lldp [ agent { nearest-customer

| nearest-nontpmr } ]
management-address-format

string

In Layer 2/Layer 3 aggregate

interface view:

lldp agent { nearest-customer

| nearest-nontpmr }
management-address-format

string

By default, the encoding format of
the management address is
numeric.

Setting other LLDP parameters

The Time to Live TLV carried in an LLDPDU determines how long the device information carried in the

LLDPDU can be saved on a recipient device.
By setting the TTL multiplier, you can configure the TTL of locally sent LLDPDUs, which determines how

long information about the local device can be saved on a neighboring device. The TTL is expressed by
using the following formula:
TTL = Min (65535, (TTL multiplier × LLDP frame transmission interval + 1))
As the expression shows, the TTL can be up to 65535 seconds. TTLs greater than 65535 will be rounded

down to 65535 seconds.
To change LLDP parameters: