Troubleshooting sflow configuration, Symptom, Analysis – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 362: Solution

Advertising
background image

32-4

GE0/0/1 Both 100000 Random Active

Troubleshooting sFlow Configuration

The Remote sFlow Collector Cannot Receive sFlow Packets

Symptom

The remote sFlow collector cannot receive sFlow packets.

Analysis

z

sFlow is not enabled globally because the sFlow agent or/and the sFlow collector are not specified.

z

No port is enabled with sFlow to sample data.

z

The IP address of the sFlow collector specified on the sFlow agent is different from that of the
remote sFlow collector.

z

No IP address is configured for the Layer 3 interface on the device, or the IP address is configured,
but the UDP packets with the IP address being the source cannot reach the sFlow collector.

z

The physical link between the device and the sFlow collector fails.

Solution

1) Check whether sFlow is correctly configured by displaying sFlow configuration with the display

sflow

command.

2) Check whether the correct IP address is configured for the device to communicate with the sFlow

collector.

3) Check whether the physical link between the device and the sFlow collector is normal.

Advertising