Configuration procedure

# Enter the OAP board view from the user view of the WX6103 main control board.

<WX6103> oap connect slot 0

Connected to OAP!

<H3C>

# Enter system view of the OAP board, and enable the Telnet service.

<H3C> system-view

[H3C] telnet server enable

# Enter VTY 0 user interface view.

[H3C] user-interface vty 0

# Configure to authenticate users logging in to VTY 0 using the local password.

[H3C-ui-vty0] authentication-mode password

# Set the local password to 123456 (in plain text).

[H3C-ui-vty0] set authentication password simple 123456

# Specify commands of level 2 are available to users logging in to VTY 0.

[H3C-ui-vty0] user privilege level 2

# Configure Telnet protocol is supported.

[H3C-ui-vty0] protocol inbound telnet

# Set the maximum number of lines the screen can contain to 30.

[H3C-ui-vty0] screen-length 30

# Set the maximum number of commands the history command buffer can store to 20.

[H3C-ui-vty0] history-command max-size 20

# Set the timeout time to 6 minutes.

[H3C-ui-vty0] idle-timeout 6

Telnet Configuration with Authentication Mode Being Scheme