# Configure Telnet protocol is supported.

[device-ui-vty0] protocol inbound telnet

# Set the maximum number of lines the screen can contain to 30.

[device-ui-vty0] screen-length 30

# Set the maximum number of commands the history command buffer can store to 20.

[device-ui-vty0] history-command max-size 20

# Set the timeout time to 6 minutes.

[device-ui-vty0] idle-timeout 6

Telnet Configuration with Authentication Mode Being Password

Configuration Procedure

Follow these steps to perform Telnet configuration with the authentication mode being password:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter one or more VTY user
interface views

user-interface vty

first

-number [ last-number ]

Configure to authenticate users
logging in to VTY user interfaces
using the local password

authentication-mode
password

Required

Set the local password

set authentication password

{ cipher | simple } password

Required

Configure the command level
available to users logging in to the
user interface

user privilege level

level

Optional
By default, commands of level 0 are
available to users logging in to VTY
user interface.

Configure the protocol to be
supported by the user interface

protocol inbound

{ all | ssh |

telnet

}

Optional
By default, both Telnet protocol and
SSH protocol are supported.

Set the commands to be executed
automatically after a user login to
the user interface successfully

auto-execute command

text

Optional
By default, no command is executed
automatically after a user logs into the
VTY user interface.

Make terminal services available

shell

Optional
By default, terminal services are
available in all user interfaces.

Set the maximum number of lines
the screen can contain

screen-length

screen-length

Optional
By default, the screen can contain up
to 24 lines.
You can use the screen-length 0
command to disable the function to
display information in pages.

Set the history command buffer size

history-command max-size

value

Optional
The default history command buffer
size is 10. That is, a history command
buffer can store up to 10 commands
by default.