H3C Technologies H3C WX3000 Series Unified Switches User Manual

Page 588

Advertising
background image

58-9

To do…

Use the command…

Remarks

Configure the maximum number of
history records that can be saved

history-records

number

Optional
By default, the maximum number is
50.

Configure the automatic test
interval

frequency interval

Optional
By default, the automatic test
interval is zero seconds, indicating
no automatic test will be made.

Configure the probe timeout time

timeout

time

Optional
By default, a probe times out in
three seconds.

Configure the type of service

tos value

Optional
By default, the service type is zero.

Configure the type of HTTP
operation

http-operation

{ get | post }

Optional
By default, the type of HTTP
operation is get, that is, the HTTP
operation will get data from the
HTTP server.

Start the test

test-enable

Required

Display test results

display hwping results
[ admin-name operation-tag ]

Required
You can execute the command in
any view.

5) Configuring jitter test on HWPing client

Follow these steps to configure jitter test on HWPing client:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable the HWPing client function

hwping-agent enable

Required
By default, the HWPing client
function is disabled.

Create a HWPing test group and
enter its view

hwping

administrator-name

operation-tag

Required
By default, no test group is
configured.

Configure the destination IP
address

destination-ip

ip-address

Required
The destination address must be
the IP address of a UDP listening
service on the HWPing server.
By default, no destination address
is configured.

Configure the destination port

destination-port

Port-number

Required
The destination port must be the
port of a UDP listening service on
the HWPing server.
By default, no destination port is
configured.

Configure the source IP address

source-ip

ip-address

Optional
By default, no source IP address is
configured.

Advertising