Displaying and maintaining monitor link, Monitor link configuration example, 5 monitor link configuration example – H3C Technologies H3C WX3000 Series Unified Switches User Manual

Page 628

Advertising
background image

61-5

z

A Smart Link/Monitor Link group with members cannot be deleted. A Smart Link group as a Monitor
Link group member cannot be deleted.

z

The Smart Link/Monitor Link function and the remote port mirroring function are incompatible with
each other.

z

If a single port is specified as a Smart Link/Monitor Link group member, do not use the lacp enable
command on the port or add the port to another dynamic link aggregation group because doing so
will cause the port to become an aggregation group member.

z

Using the copy command on a port does not copy the Smart Link/Monitor Link group member
information configured on the port to any other port.

Displaying and Maintaining Monitor Link

To do…

Use the command…

Remarks

Display the information about one
or all Monitor Link groups

display monitor-link group
{ group-id | all }

Available in any view

Monitor Link Configuration Example

Implementing Collaboration Between Smart Link and Monitor Link

Network requirements

As shown in

Figure 61-3

, the PCs access the server and Internet through the device. Configure Smart

Link and Monitor Link to prevent the PCs from failing to access the server and Internet due to uplink link
or port failure.

Advertising