H3C Technologies H3C WX3000 Series Unified Switches User Manual

Page 548

Advertising
background image

51-12

To do…

Use the command…

Remarks

Configure the output rules of
system information

info-center source

{ modu-name |

default

} channel

{ channel-number | channel-name }
[ { log | trap | debug } { level
severity

| state state } ]*

Optional
Refer to

Table 51-4

for the default

output rules of system information.

Set the format of time stamp in the
output information

info-center timestamp

{ log | trap

| debugging } { boot | date |
none

}

Optional
By default, the time stamp format
of the output trap information is
date

.

Setting to Output System Information to the Log Buffer

Follow these steps to set to output system information to the log buffer:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable the information center

info-center enable

Optional
Enabled by default.

Enable information output to the
log buffer

info-center logbuffer

[ channel

{ channel-number | channel-name }
| size buffersize ]*

Optional
By default, the device uses
information channel 4 to output log
information to the log buffer, which
can holds up to 512 items by
default.

Configure the output rules of
system information

info-center source

{ modu-name |

default

} channel

{ channel-number | channel-name }
[ { log | trap | debug } { level
severity

| state state } ]*

Optional
Refer to

Table 51-4

for the default

output rules of system information.

Set the format of time stamp in the
output information

info-center timestamp

{ log | trap

| debugging } { boot | date |
none

}

Optional
By default, the time stamp format
of the output log information is
date

.

Setting to Output System Information to the SNMP NMS

Follow these steps to set to output system information to the SNMP NMS:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable the information center

info-center enable

Optional
Enabled by default.

Enable information output to the
SNMP NMS

info-center snmp channel

{ channel-number | channel-name }

Optional
By default, the device outputs trap
information to SNMP through
channel 5.

Advertising