Menu list – Roland VR-120HD Direct Streaming AV Mixer User Manual

Page 129

Advertising
background image

129

Menu List

Menu item

Value

(bold text: default value)

Explanation

Lo Freq

20.0Hz–

100Hz

–2.00kHz

Adjusts the center frequency when changing the tone quality in the low band.

Compressor/Limiter

OFF

, ON

Turns the compressor or limiter on/off.

Type

Selects the compressor or limiter.

Compressor

Effect

Audio that exceeds the specified threshold level is compressed. This reduces the difference

between the maximum volume and minimum volume, making the audio more comfortable

for listening

Limiter

Effect

Compresses the audio so that the mixed audio does not exceed the specified threshold level.

* Distortion will occur if audio that exceeds the allowable range of the limiter is input.

Compressor

Threshold

-50–

-8

–0dB

Specifies the level used as the threshold at which the compressor is applied. Compression is

applied to audio that exceeds the threshold.

Ratio

1.00: 1, 1.12: 1, 1.25: 1, 1.40: 1,
1.60: 1, 1.80: 1, 2.00: 1,

2 .50: 1

,

3.20: 1, 4.00: 1, 5.60: 1, 8.00: 1,
16.0: 1, INF: 1

Specifies the degree of compression applied to the audio. The state in which no compression

is applied is defined as “1”.

Attack

0.0–

30

–100ms

Specifies the time until compression starts when audio exceeding the threshold is input.

Release

30–

250

–5000ms

Adjusts the length of time until compression ends after audio falls below the threshold.

Makeup Gain

-40–

0

–40dB

Adjusts the final output volume level after applying the compressor.

Limiter

Threshold

-40–

-6

–0dB

Adjusts the level that becomes the threshold at which the limiter is applied. Compression

is applied to audio that exceeds the threshold. The volume level of audio that is output is

limited so as to stay to below the threshold.

Loudness Auto Gain

Control

OFF

, ON

Turns loudness auto gain control on/off.

Effect

The long-term average loudness is measured, and the volume is adjusted so that it is

appropriate overall.

Integrated Gain

Control

Disable,

Enable

Specifies whether the extended interval auto control is enabled (Enable) or disabled

(Disable).

Sens

0–

80

–127

Adjusts the speed at which the target level (Target LKFS) is approached.

Momentary Gain

Control

Disable,

Enable

Specifies whether the momentary auto control is enabled (Enable) or disabled (Disable).

Sens

0–

80

–127

Adjusts the speed at which the target level (Target LKFS) is approached.

Target LKFS

-34–

-24

–-10dB

Specifies the target loudness value.

Adaptive Noise

Reduction

OFF

, ON

Turns Adaptive Noise Reduction on/off.

Effect

By continuously monitoring the input audio to detect noise during periods of silence, this

removes only the noise component.

Depth

0–

80

–127

Specifies the strength at which noise reduction is applied.

Talking Detector

0–

80

–127

Specifies the sensitivity of the talking detector.
Higher values raise the sensitivity, so that it will be easier to detect the presence or absence

of talking even in a noisy environment.

Auto Learn

Disable,

Enable

Enables automatic noise detection.

Manual Measure

Exec

Performs noise detection manually.

Forget Learning

Exec

Resets the learned parameters.
Reset applies to the parameters of both adaptive noise reduction and loudness auto gain

control.

Lo Frequency Cut

OFF

, ON

Turns Lo Frequency Cut on/off.

Advertising