Hardware Reference Manual

Intel

®

IXP2800 Network Processor

Media and Switch Fabric Interface

The

src_op_1

and

src_op_2

operands are added together to form the address in RBUF (note that

the base address of the RBUF is 0x2000). The

ref_cnt

operand is the number of 32-bit words or

word pairs, that are pushed into two sequential S_TRANSFER_IN registers, starting with

$s_xfer_reg

.

Using the data in RBUF in

Table 87

above, reading eight bytes from offset 0 into transfer registers

0 and 1 would yield the result in

Example 34

.

Microengine can move data from RBUF to DRAM using the instruction:

dram[rbuf_rd, --, src_op1, src_op2, ref_cnt], indirect_ref

The

src_op_1

and

src_op_2

operands are added together to form the address in DRAM, so the

dram

instruction must use the

indirect_ref

modifier to specify the RBUF address (refer to the

IXP2800 Network Processor chassis chapter for details). The

ref_cnt

operand is the number of

64-bit words that are read from RBUF.

Using the data in RBUF in

Table 87

above, reading 16 bytes from offset 0 in RBUF into DRAM

would yield the result in

Example 35

in DRAM (addresses in DRAM must be aligned to

8-byte units. The data from lower-offset RBUF offsets goes into lower addresses in DRAM.)

For both types of RBUF read, reading an element does not modify any RBUF data, and does not
free the element, so buffered data can be read as many times as desired.

8.2.2.1

SPI-4

SPI-4 data is placed into RBUF as follows:

At chip reset all elements are marked invalid (available).

When a SPI-4 Control Word is received (i.e., when RCTL is asserted) it is placed in a
temporary holding register. The Checksum accumulator is cleared. The subsequent action is

based on the Type field.

— If Type is Idle or Training, the Control Word is discarded.

— If Type is not Idle or Training:

An available RBUF element is allocated by receive control logic.(If there is no available

element, the data is discarded and MSF_Interrupt_Status[RBUF_Overflow is set.) Note
that this normally should not happen because, when the number of RBUF elements falls

below a programmed limit, the flow control status is sent back to the PHY device (refer to

Example 34. Data from RBUF Moved to Microengine Transfer Registers

Transfer
Register

Number

Bit Number within Transfer Register

31

24 23

16 15

8 7

0

0

0

1

2

3

1

4

5

6

7

Example 35. Data from RBUF Moved to DRAM

63

56 55

48 47

40 39

32 31

24 23

16 15

8 7

0

4

5

6

7

0

1

2

3

C

D

E

F

8

9

A

B