Intel NETWORK PROCESSOR IXP2800 User Manual

Page 400

Advertising
background image

400

Hardware Reference Manual

Intel

®

IXP2800 Network Processor

Performance Monitor Unit

97

Rx null autopush

P_CLK

pulse

separate

98

Tx skip

P_CLK

pulse

separate

An mpacket was dropped due to the
Tx_Skip bit being set in the Transmit Control
Word.

99

SF_CRDY

P_CLK

level

separate

Only valid in CSIX receive mode and
indicates how much of the time the switch
fabric is able to receive control CFrames.

100

SF_DRDY

P_CLK

level

separate

Only valid in CSIX receive mode and
indicates how much of the time the switch
fabric is able to receive data CFrames.

101

TM_CRDY

P_CLK

level

separate

Only valid in CSIX receive mode; indicates
how much of the time the egress processor
is able to receive control CFrames.

102

TM_DRDY

P_CLK

level

separate

Only valid in CSIX receive mode; indicates
how much of the time the egress processor
is able to receive data CFrames.

103

FCIFIFO enqueue

P_CLK

pulse

separate

104

FCIFIFO dequeue

P_CLK

pulse

separate

105

FCIFIFO error

P_CLK

pulse

separate

Indicates that a bad CFrame was received
on the CBus (horizontal or vertical parity
error, premature RxSOF); only valid in CSIX
transmit mode.

106

FCIFIFO synchronizing
FIFO error

P_CLK

pulse

separate

Indicates that the CBus ingress logic
encountered a FCIFIFO full condition while
enqueueing a CFrame into FCIFIFO.

107

Vertical parity error

P_CLK

pulse

separate

Only valid in CSIX receive mode.

108

Horizontal parity

P_CLK

pulse

separate

Only valid in CSIX receive mode.

109

Dip 4 Parity Error

P_CLK

pulse

separate

Only valid in SPI-4 receive mode.

110

Dip 2 Parity Error

P_CLK

pulse

separate

Only valid in SPI-4 receive mode.

111

reserved

112

CSIX DATA receive active

MR_CLK

level

separate

Indicates a valid CSIX DATA CFRAME
received on the RX_DATA bus and may be
used to measure bus utilization; the active
signal from the MR_CLK domain is
synchronized; as such, it yields an
approximate value.

113

CSIX CONTROL
receive active

MR_CLK

level

separate

Indicates a valid CSIX CONTROL CFRAME
received on the RX_DATA bus and may be
used to measure bus utilization; the active
signal from the MR_CLK domain is
synchronized; as such, it yields an
approximate value.

114

SPI-4 receive active

MR_CLK

level

separate

Indicates a valid SPI-4 Packet received on
the RX_DATA bus and may be used to
measure bus utilization; the active signal
from the MR_CLK domain is synchronized;
as such, it yields an approximate value.

Table 157. IXP2800 Network Processor MSF PMU Event List (Sheet 5 of 6)