5.4

Curl Adjustment (Relay Unit RU-508)

5

bizhub PRESS C8000/e

5-50

% If you do not make the mechanical curl adjustment, select [0].

% Pressing [Reset] sets the mechanical curl adjustment value to [0] for all trays.

5

Specify whether or not to make the humidification curl adjustment.

To make the humidification curl adjustment, select [ON] on the right side of "Humidifier Setting", or se-
lect [OFF] if not.

% With [Humidifier HM-101] mounted, the machine will be reset as described in the table below.

NOTICE

The machine can be set to select [OFF] for the humidification curl adjustment for plain and fine paper
types when [Reset] is pressed. Contact your service representative, if desired. With this setting made,
the humidification curl adjustment for plain and fine paper types is set to [OFF] by default.

6

Press [OK].

The Machine Screen will be restored.

Paper Type

Weight

Humidification curl adjust-
ment ON/OFF

Plain, Fine

64 g/m

2

to 350 g/m

2

ON

Color Specific
Coated-GL/ML/GO/MO

64 g/m

2

to 135 g/m

2

Unavailable

136 g/m

2

to 350 g/m

2

OFF

Advertising