5.4
Curl Adjustment (Relay Unit RU-508)
5
bizhub PRESS C8000/e
5-50
% If you do not make the mechanical curl adjustment, select [0].
% Pressing [Reset] sets the mechanical curl adjustment value to [0] for all trays.
5
Specify whether or not to make the humidification curl adjustment.
To make the humidification curl adjustment, select [ON] on the right side of "Humidifier Setting", or se-
lect [OFF] if not.
% With [Humidifier HM-101] mounted, the machine will be reset as described in the table below.
NOTICE
The machine can be set to select [OFF] for the humidification curl adjustment for plain and fine paper
types when [Reset] is pressed. Contact your service representative, if desired. With this setting made,
the humidification curl adjustment for plain and fine paper types is set to [OFF] by default.
6
Press [OK].
The Machine Screen will be restored.
Paper Type
Weight
Humidification curl adjust-
ment ON/OFF
Plain, Fine
64 g/m
2
to 350 g/m
2
ON
Color Specific
Coated-GL/ML/GO/MO
64 g/m
2
to 135 g/m
2
Unavailable
136 g/m
2
to 350 g/m
2
OFF