9.11

[04 Density Balance Adjustment]

9

9.11

[04 Density Balance Adjustment]

9.11.1

[01 Density Balance Chart Output]

There are two methods of density balance adjustment in crosswise direction.

-

Create colorimetric data using Spectrophotometer i1iSis XL or i1Pro, then register the data on the ma-
chine.

-

Register the density balance data manually.

The colorimetric data can be created and measured by the following procedure.

-

Output the density balance chart from the machine.

-

Load the density balance chart into the spectrophotometer.

-

Create colorimetric data using the data loaded into the spectrophotometer.

-

Register the colorimetric data on the machine using a USB flash drive.

This section describes how to output the density balance chart to be loaded into the spectrophotometer.

Setting items in Density Balance Chart Output

-

Two spectrophotometers are provided; Spectrophotometer i1iSis XL and Spectrophotometer i1Pro.
Select the desired one.

-

Two types of chart, Type 1 (simple checking chart) and Type 2 (detailed checking chart), are provided
for each spectrophotometer. Select the desired one.

-

Output a chart individually for each of predefined screen types. [Stochastic], however, cannot be se-
lected to output a chart.

d

Reference

Specify whether to allow or restrict the use of four screens individually in the User Setting. Dot 1, one of the
four screens, cannot be restricted. See page 10-59
for details.

The dot screen and line screen are provided with five types for each, and one for each can be specified in the
Administrator Setting. See page 10-79