9.2

[01 Machine Adjustment]

9

bizhub PRESS C8000/e

9-18

10

Use the touch panel keypad or control panel keypad to enter the setting data.

% Use [+/-] to specify the value to be positive or negative.

% Press [Set] to change the current data.

% Adjustable range: ADF Centering-Front, ADF Centering-Back -60 (Front) to +60 (Back) (1 step = 0.1

mm) Adjustable range: Orig. Glass Centering -30 (Front) to +30 (Back) (1 step = 0.1 mm)

11

Repeat the steps from 4 to 10 until the desired result is obtained.

12

Press [Return] to restore the Scan Adjustment Menu Screen.

9.2.7

[02 Scan Adjustment] - [03 FD-Mag. Adjustment]

Adjust the magnification in paper feed direction when scanning the original from the original glass.

NOTICE

Make this adjustment after completing [01 Machine Adjustment] - [01 Printer Adjustment] - [03 FD-Mag. Ad-
justment].

1

Press [Adjustment] on the Machine Screen to display the Adjustment Menu Screen.

2

Press [01 Machine Adjustment], [02 Scan Adjustment], and [03 FD-Mag. Adjustment] in sequence.

The FD-Mag. Adjustment Screen will be displayed.

3

Press [Print Mode].

4

Load A3 w paper into a tray, then select that tray key.

5

Place the test chart on the original glass, then press Start on the control panel. A sample pattern will
be output.

6

Check the misalignment by comparing the original and the output.

Allowance: 0 +/- 0.5% or less (full size)

Within 205.7 +/- 1 mm

7

If any adjustment is required, press [Exit Print Mode] to return to the FD-Mag. Adjustment Screen.

8

Use the touch panel keypad or control panel keypad to enter the setting data.

% Use [+/-] to specify the value to be positive or negative.

% Press [Set] to change the current data.

% Adjustable range: -40 (Short) to +40 (Long) (1 step = 0.05%)

9

Repeat the steps from 3 to 8 until the desired result is obtained.

10

Press [Return] to restore the Scan Adjustment Menu Screen.

Advertising