Konica Minolta bizhub PRESS C8000e User Manual

Page 397

Advertising
background image

bizhub PRESS C8000/e

9-79

9.11

[04 Density Balance Adjustment]

9

4

Press [02 Density Balance Data Reg/Del] on the Density Balance Adjustment Menu Screen to display
the Density Balance Adjustment Data Register/Delete Screen.

5

Select the desired number of row from the 10 on the list.

NOTICE

No more than 10 pieces of data can be registered, however, the data can be overwritten. If desired, se-
lect the data to be overwritten.

NOTICE

The colorimetric data can be synthesized and registered. To synthesize data, select the row having the
same screen type, paper type, and weight.

6

Press [Measured data load].

A dialog appears to prompt you to connect the USB flash drive.

7

Connect the USB flash drive stored with the measured data into
the USB port of the machine.

% This port is available for low-power devices only. Please

provide an external supply of power for devices that require
a large amount of power.

8

Press [OK].

The file name of the measured data will be displayed on the Density Balance Adjustment Data Regis-
ter/Delete Screen.

9

Select the file name of the data to be registered, then press [OK].

With a row of the existing data selected in step 5, a confirmation dialog will be displayed.

% To replace the selected data by the new data, press [Overwrite].

% To synthesize the selected data with the new data, press [Combination]. If any discrepancy occurs

in screen type, paper type, or weight, [Combination] will appear grayed out.

% To stop overwriting or synthesizing the data, press [Cancel].

The Density Balance Adjustment Data Register/Delete Screen will be restored, showing (up to 21 char-
acters of user-customized information) specified in step 2 as [Adj. Data Profile Name].

% You can change the Adj. Data Profile Name, if desired. Press [Change Name] to display the Change

Profile Name Screen. Enter the desired profile name, then press [OK].

10

Press [Return] to restore the Density Balance Adjustment Menu Screen.

Editing and registering existing density balance data manually

Follow the procedure below to edit and register the existing density balance data manually.

Adjustment points: 9 points in [All e 9 points], 512 points in [16 e 32 points]

Adjustable range: -128 to +127

-

For manual setting of the density balance adjustment, the following two modes, [All e 9 points] and [16
e 32 points], are provided.

-

Use [All e 9 points] to enter the density value into 9 points out of 32 points dividing the crosswise direc-
tion, so that the machine automatically determines the density value in surrounding area.

-

Use [16 e 32 points] to manually enter the density value into a total of 512 points; 32 points in crosswise
direction, and 16 points in feeding direction.

-

This setting can be made individually for each of predefined screen types. The five screen types pro-
vided to [Stochastic] are [ED 1], [ED 2], [ED 3], [FM 1], and [FM 2], all of which cannot be used for any
screen.

Advertising