Registering new density balance data manually – Konica Minolta bizhub PRESS C8000e User Manual

Page 400

Advertising
background image

9.11

[04 Density Balance Adjustment]

9

bizhub PRESS C8000/e

9-82

11

Select the paper size.

% Load 12 e 18 w, SRA3 w, 11 e 17 w, or A3 w paper in a tray, then select that tray.

12

Press Start on the control panel.

The machine will output a chart with its density balance adjusted.

13

Press [Exit Print Mode] to return to the Density Balance Manual Setting Screen.

14

Check the chart output in step 12, then repeat steps 5 to 13 till the desired density balance is obtained.

15

When the adjustment is completed, press [OK] on the Density Balance Manual Setting Screen.

NOTICE

Without [OK] pressed after output of the chart, the colorimetric data will not be changed and registered.
Be sure to press [OK].

The Density Balance Adjustment Data Register/Delete Screen will be restored.

16

To change the profile name, press [Change Name].

The Change Profile Name Screen will be displayed.

% Enter the desired profile name, then press [OK].

17

Press [Return] to restore the Density Balance Adjustment Menu Screen.

Registering new density balance data manually

Follow the procedure below to register the new density balance data manually.

Adjustment points: 9 points in [All e 9 points], 512 points in [16 e 32 points].

Adjustable range: -128 to +127

-

For manual setting of the density balance adjustment, the following two modes, [All e 9 points] and [16
e 32 points], are provided.

-

Use [All e 9 points] to enter the density value into 9 points out of 32 points dividing the crosswise direc-
tion, so that the machine automatically determines the density value in surrounding area.

-

Use [16 e 32 points] to manually enter the adjustment data into a total of 512 points; 32 points in cross-
wise direction, and 16 points in feeding direction.

-

This setting can be made individually for each of predefined screen types. The five screen types pro-
vided to [Stochastic] are [ED 1], [ED 2], [ED 3], [FM 1], and [FM 2], all of which cannot be used for any
screen.

d

Reference

Specify whether to allow or restrict the use of the four screens individually in the User Setting. Dot 1, one of
the four screens, cannot be restricted. See page 10-59 for de
tails.

The dot screen and line screen are provided with five types for each, and one for each can be specified in the
Administrator Setting. See page 10-79 for de
tails.