5 [security] tab, 1 authentication, Security] tab -15 – Konica Minolta bizhub PRESS C8000e User Manual
Page 589: Authentication -15
bizhub PRESS C8000/e
12-15
12.5
[Security] Tab
12
12.5
[Security] Tab
The [Security] tab provides the information and settings concerning the security of the machine.
12.5.1
Authentication
Click [Authentication], then [User Auth/Account Track] on the menu of [Security] tab to display this page.
This page allows you to make settings concerning the user authentication/account track.
Specification
Description
General Settings
Specify whether or not to activate the user authentication function on
the machine. Selecting [ON (MFP)] sets the machine to ask the user au-
thentication procedure before use.
Public User Access
Specify whether or not to allow users to operate the machine without
being authenticated by using an IC card as well as entering a user pass-
word, account name, or account password.
Account Track
Specify whether or not to activate the account track function on the ma-
chine. Selecting [ON] sets the machine to ask the account authentica-
tion procedure before use.
Account Track Input Method
Set the machine to require [Account Name & Password] or [Password
Only] when the account track function is activated.
Synchronize User Authentica-
tion & Account Track
Specify whether or not to synchronize the user authentication and ac-
count track functions.
Number of Counters Assigned
for Users
Specify the number of user authentication. The total number of authen-
tication is 1,000 and to be distributed between users and accounts;
consequently the number of account authentication will be the remain-
ing after the number specified here is subtracted.
Upper Limit Achieve Move-
ment
Select the action of the machine when the specified limit count is
reached in a job operated by each user or account. The upper limit can
be specified in the operation of User Registration or Account Track Reg-
istration.
Sample Print
Specify whether or not to include the page count of sample prints into
the counter.
[OK]
Click to complete the setting.
[Cancel]