Communicating with Devices on an Ethernet Network 11-13

Using BOOTP to Configure Channel 2 for Controllers on Subnets

Configure the BOOTPTAB file according to the subnet mask and gateway
address for each PLC-5E controller on the link. See the example below and the
corresponding BOOTPTAB file on the next page.

IMPORTANT

Because BOOTP requests are seen only on the local
subnet, each subnet needs its own BOOTP server and
BOOTPTAB file.

Ethernet gateway
or router"

PLC-5/20E
processor

Ethernet TCP/IP network

personal computer WINDOWS
or HP 9000 or VAX computer

PLC-5/80E
processor

Hostname: Iota2
IP address: 130.151.132.110
Subnet Mask: 255.255.255.0
Gateway
Address: 130.151.132.1

PLC-5/20E
processor

Hostname: Iota3
IP address: 130.151.138.123
Subnet Mask: 255.255.255.0
Gateway
Address: 130.151.138.1

Hostname: Iota1
IP address: 130.151.194.19
Subnet Mask: 255.255.255.0
Gateway Address: 130.151.194.1

130.151.194.xxx

130.151.132.xxx

130.151.138.xxx

Subnet A

Subnet B

Subnet C

BOOTP
server

BOOTP
server

BOOTP
server

130.151.132.1

130.151.138.1

130.151.194.1