Publication 1785-UM012D-EN-P - July 2005

6-6 Communicating with Remote I/O

I/O Link Devices that Require 150

Termination Resistors

Configuring a Controller
Channel as a Scanner

Use this table to help you determine the controller channels you can configure
as a remote I/O scanner:

To configure a controller channel as a scanner, you:

define an I/O status file, which stores information about the racks
connected to the controller, by using the controller configuration screen
in your programming software

specify the scanner’s communication rate and diagnostic file and define a
scan list by using the scanner mode channel configuration screen in your
programming software

Device Type

Catalog Number

Series

Scanners

1771-SN
1772-SD, -SD2
1775-SR
1775-S4A, -S4B
6008-SQH1, -SQH2

All

Adapters

1771-AS

1771-ASB

A

1771-DCM

All

Miscellaneous 1771-AF

Controller

Channels that Support
Remote I/O Scanner

PLC-5/11

1A

PLC-5/20

PLC-5/20E

1B

PLC-5/30
PLC-5/40L
PLC-5/60L

PLC-5/40E

PLC-5/80E

1A, 1B

PLC-5/40
PLC-5/60
PLC-5/80

1A, 1B, 2A, 2B