Rockwell Automation 1785-Lxxx Enhanced and Ethernet PLC-5 Programmable Controllers User Manual
Page 337

Publication 1785-UM012D-EN-P - July 2005
Instruction Set Quick Reference D-37
Category
Code
Title
Time (
µ
s)
Integer
Time (
µ
s)
Floating Point
Words of
Memory
(1)
True
False
True
False
ASCII
(2)
AIC
integer to string
• PLC-5/11, -5/20,
and -5/20E
• PLC-5/30, -5/40,
-5/40E, -5/40L
-5/60, -5/60L,
-5/80, and -5/80E
• 260
• 270
1.4
3-5
ARD
read characters
• PLC-5/11, -5/20,
and -5/20E
• PLC-5/30, -5/40,
-5/40E, -5/40L
-5/60, -5/60L,
-5/80, and -5/80E
• 315
• 380
• 214
• 149
4-7
ARL
read line
• PLC-5/11, -5/20,
and -5/20E
• PLC-5/30, -5/40,
-5/40E, -5/40L
-5/60, -5/60L,
-5/80, and -5/80E
• 316
• 388
• 214
• 151
4-7
ASC
string search
• PLC-5/11, -5/20,
and -5/20E
• PLC-5/30, -5/40,
-5/40E, -5/40L
-5/60, -5/60L,
-5/80, and -5/80E
• 222 + C[1.7]
• 151 + C[3.0]
1.9
5-9
ASR
string compare
• PLC-5/11, -5/20,
and -5/20E
• PLC-5/30, -5/40,
-5/40E, -5/40L
-5/60, -5/60L,
-5/80, and -5/80E
• 234 + C[1.3]
• 169 + C[2.4]
• 202
• 119
3-5
(1)
Use the larger number for addresses beyond 2048 words in the controller’s data table.
(2)
Timing for ASCII instructions is the time for the instruction to queue-up for processing in channel 0.
C = number of ASCII characters