Chapter 16 - using main control programs, Using main control programs, Using this chapter – Rockwell Automation 1785-Lxxx Enhanced and Ethernet PLC-5 Programmable Controllers User Manual

Page 253: Selecting main control programs, Apter 16, Chapter, Using this chapter selecting main control programs

Advertising
background image

1

Publication 1785-UM012D-EN-P - July 2005

Chapter

16

Using Main Control Programs

Using This Chapter

Selecting Main Control
Programs

You can have as many as 16 control programs active at one time. Each of
these programs is called a “main control program” (MCP). You can define
one MCP for each particular machine or function of your process. This lets
you separate sequential function charts (SFCs), ladder logic, and structured
text to better modularize your process and make troubleshooting easier.

A main control program can be an SFC numbered 1-999; it can also be a
ladder or structured-text program numbered 2-999 in any program file. You
can use any mix of SFC, ladder, and structured-text programs to define 16
main control programs. One data table is used by all MCPs (i.e., you do not
have a separate data table for each MCP).

For Information About

Go to Page

Selecting main control programs

16-1

Understanding how the controller interprets
MCPs

16-2

Configuring MCPs

16-3

Monitoring MCPs

16-5

Consider Using this Technique

If You are

SFC

defining the order of events in the process

Ladder Logic

• more familiar with ladder logic than with programming

languages such as BASIC

• performing diagnostics

Structured Text

• more familiar with programming languages such as

BASIC than with ladder logic

• using complex mathematical algorithms
• using program constructs that repeat or “loop”
• creating custom data-table monitoring screens