Buhler 2425 User Manual

Page 108

Advertising
background image

SECTION 2 - OPERATION

2-50

Electronic Monitor

The electronic monitor, 1, is an LCD (Liquid

Crystal Display) that is divided into two sections;

an upper section, 2, and a lower section, 3.
The upper section of the monitor is dedicated to

providing engine RPM readout at all times during

normal tractor operation, regardless of the

position of the rotary select switch.
The lower section of the monitor is dedicated to

providing six different readouts, based on the

position of the rotary select switch during normal

tractor operation.
The electronic monitor also has an audible alarm

which will call the operator’s attention to the

Electronic Instrument Control System.

Figure 2-74

2

1

3

Electronic

Monitor

Acknowledge/Reset

Button

The electronic monitor acknowledge/reset

button is a push-button two-position momentary

switch that allows the operator to acknowledge

information

provided

by

the

Electronic

Instrument Control System. The button is also

used during the calibration procedure.

Figure 2-75

Electronic Monitor Rotary Select Switch

The electronic monitor rotary select switch is a

six-position rotary switch used to select LCD

readouts on the lower half of the electronic

monitor.
1 Electrical system voltage
2 PTO speed
3 Tractor ground speed
4 Service interval one
5 Service interval two
6 Tractor accumulated hours
The rotary select switch is active at all times

during normal operation of the tractor.

Figure 2-76

1

2

3

4

5

6

Advertising