If engine oil pressure continues to drop and

reaches 100 kPa (15 psi), the EICS will react as

detailed in “Low Engine Oil Pressure (below 100

kPa (15 psi)) at Any Engine Speed” in this

manual.

The Operator cannot cancel or interrupt the

derate sequence from occurring on the engine.

The module does not recognize activation of,

nor is it tied into the EICS acknowledge/reset

button on the dash of the tractor.

If the tractor is shut down and then restarted, and

the alarm condition still exists, (low engine oil

pressure at engine speeds above 1200 rpm) the

module will repeat the derate sequence. If the

tractor is restarted and the alarm condition has

been corrected, the tractor will return to normal

operation. If the tractor is not shut down, and the

alarm condition is corrected, the tractor will

return to normal operation without having to shut

it off and restart it.