Buhler 2425 User Manual

Page 121

Advertising
background image

SECTION 2 - OPERATION

2-63

D. Add the two measurements taken and

divide by two to give an average rolling

radius value. Round this value to the

nearest tenth (0.1).
EXAMPLE

Axle #1

87 cm (34.25″)

Axle #2

86 cm (33.75″)

Total

173 cm (68.00″) ÷ 2 = 86 cm

(34.00″)

Rounded Totals 86 cm (34.0″)

E. To place the value into the monitor, use the

digit select switch to select the necessary

numbers. The monitor will accept values

between 50.8 cm and 127.0 cm (20.0″ and

50.0″).

F. Push the acknowledge/reset button again

to enter the value into the monitor’s

memory. The display will now go to

“Programming Units of Ground Speed

Measurement.” If no further calibration is

needed, turn the ignition to the “OFF”

position. If further calibration is needed in

other areas, select the area to be

calibrated with the rotary select switch and

proceed as detailed for that switch

position.

Advertising