2-131

When using a double-acting cylinder, connect the

feed hose from the cylinder to the bottom coupler

and the return hose to the top coupler. To extend a

double-acting cylinder, pull the remote lever

rearward to position 2. To retract the cylinder,

push the lever forward to position 3. The cylinder

can be put into the float position by pushing the

remote lever full forward in position 4.

When using a single-acting cylinder, connect the

supply line to the lower coupler. To extend the

cylinder, pull the remote lever rearward to

position 2. To retract, push the control lever fully

forward to “float,” position 4.

IMPORTANT: Always use the float position to

lower a single-acting cylinder. The retract

position is for double-acting cylinders only.

Figure 2-177

To disconnect the coupler, make sure that the

remote control lever is in the neutral position and

the engine is off. Check to be sure that the

implement has its transport stops in place or is

lowered to the ground.

Grasp the coupler tip behind its hose connection

and firmly pull the tip straight back from the

coupler. Cover the tip with a protective cap to

minimize contamination.

WARNING: HYDRAULIC FLUID ESCAPING

UNDER PRESSURE CAN PENETRATE THE

SKIN

CAUSING

SERIOUS

PERSONAL

INJURY. WEAR GLOVES AND PROTECTIVE

CLOTHING

WHEN

SERVICING

HYDRAULICS.

BE

SURE

THAT

ALL

CONNECTIONS ARE TIGHT AND HOSES

AND LINES ARE UNDAMAGED.