EVERY 250 HOURS

OPERATION 27

Change the Coolant System Filter

The coolant system filter must be changed to

ensure the proper level of DCA4 (dry chemical

additive) is maintained in the engine cooling

system to provide maximum protection against

corrosion. To change the filter, proceed as

follows:

Turn the coolant shutoff valve, 1, to the “OFF”

position. Remove the radiator cap. Remove and

discard the coolant filter, 2. Clean the gasket

surface. Apply a light film of lubricating oil to the

gasket sealing surface before installing the new

coolant filter.

NOTE: All model tractors have one single

coolant system filter with a shut off valve

mounted on the right-hand side of the

engine.

WARNING:

DO

NOT

REMOVE

THE

RADIATOR CAP FROM A HOT ENGINE. HOT

STEAM WILL CAUSE SERIOUS PERSONAL

INJURY. REMOVE THE COOLANT SYSTEM

PRESSURE CAP AND CLOSE THE SHUTOFF

VALVES

BEFORE

REMOVING

THE

COOLANT FILTER. FAILURE TO DO SO CAN

RESULT IN PERSONAL INJURY FROM

HEATED COOLANT SPRAY.

NOTE: Do not allow oil to get inside the filter.

Oil will adversely affect the DCA4.

Install the filter on the filter head. Tighten the filter

until the gasket contacts the filter head surface.

Tighten the filter an additional 1/2 to 3/4 of a turn.

NOTE: Over-tightening can distort the

threads or damage the filter head. Do not use

tools to tighten the filter.

Turn the coolant shutoff valve to the “ON”

position. Operate the engine, and check for

coolant leaks. After the air has been purged from

the system, check the coolant level again.

Figure 3-45

1

2