Every 500 hours – Buhler 2425 User Manual

Page 270

Advertising
background image

SECTION 3 - LUBRICATION AND MAINTENANCE

3-46

EVERY 500 HOURS

Loosen and remove the two hose clamps

securing the suction hose, 1, to the suction

screen port. Remove the suction hose. Unscrew

the suction screen, 2, from the top of the

hydraulic tank and remove it. Cover the hole in

the tank so contaminants cannot enter.

The suction screen can be washed in a cleaning

solvent to remove any debris accumulated in it.

Reinstall the suction screen into the top of the

tank and tighten securely. Reinstall the suction

hose onto the steering pump and suction screen

and tighten the hose clamps to ensure that no air

can enter the hydraulic system.

Figure 3-64

OPERATION 42

Clean the Hydraulic Reservoir Breather

Clean the hydraulic reservoir breather, 1, so that

the hydraulic system can breathe properly.

Remove the breather from its mounting bolt and

unscrew the breather from its hose. Clean it out

using low pressure air 1.7 bar (25 PSI) or less.

Reinstall the hose and replace the breather in its

mounting location.

Figure 3-65

1