As required – Buhler 2425 User Manual

Page 299

Advertising
background image

SECTION 3 - LUBRICATION AND MAINTENANCE

3-75

AS REQUIRED

Lower the ether canister, 1, into the top of the

solenoid valve, 2; screw it in clockwise.

Tighten the ether canister hand tight only.

Once the ether canister is screwed into the

solenoid valve, secure the canister firmly by

attaching the hose clamp, 3, to the bracket and

around the canister. Tighten the hose clamp.

CAUTION: STARTING FLUID IS HIGHLY

FLAMMABLE. DO NOT USE NEAR FIRE,

SPARKS, OR FLAMES. BE SURE ALL

OPERATORS READ THE CAUTIONARY

INFORMATION ON THE CANISTER.

CAUTION: THE ETHYL ETHER USED AS

COLD

START

FLUID

IS

EXTREMELY

FLAMMABLE,

TOXIC,

AND

FATAL

IF

SWALLOWED. AVOID CONTACT WITH EYES

OR SKIN. AVOID BREATHING THE FUMES.

IF

SWALLOWED,

DO

NOT

INDUCE

VOMITING. CALL DOCTOR IMMEDIATELY.

IF COLD START FLUID ENTERS EYES OR

FUMES IRRITATE EYES, WASH EYES WITH

LARGE QUANTITIES OF CLEAN WATER FOR

15

MINUTES.

CONTACT

A

DOCTOR,

PREFERABLY

AN

EYE

SPECIALIST,

IMMEDIATELY.

Figure 3-124

1

2

3

OPERATION 74

Drain the Fuel Tanks

The fuel tanks can be drained by opening the

petcock, 1, located on the inside of each tank.

Allow the diesel fuel to drain and retighten the

petcock. Dispose of the fuel (if necessary)

according to local laws and regulations.

Figure 3-125

1

Advertising