SECTION 4 - TROUBLESHOOTING

4-8

ELECTRICAL SYSTEM

PROBLEM

POSSIBLE CAUSE

CORRECTION

Electrical system is

inoperative

Loose or corroded battery

connections.

Sulfated batteries.

Fuse or relay failure.

Ignition switch failure.

Clean and tighten connections.

Check each battery open circuit

voltage for 12.6 volts minimum.

Check electrolyte level and

specific gravity.

Check fuse panel.

Contact Buhler Versatile dealer.

Starter speed low and

engine cranks slowly

Loose or corroded connections.

Low battery output.

Incorrect viscosity engine oil.

Defective starter.

Clean and tighten connections.

Check each battery open circuit

voltage for 12.6 volts minimum.

Check electrolyte level and

specific gravity of each battery.

Use correct viscosity oil for

temperature conditions.

Contact Buhler Versatile dealer.

Starter inoperative

Transmission speed lever in gear.

Park brake not engaged.

Loose or corroded connections.

Dead batteries.

PTO (option) switch on.

Incorrect ignition operation.

Neutral start switch or PTO switch

malfunction.

Place shift lever in neutral.

Engage park brake.

Clean and tighten loose

connections.

Charge or replace batteries.

Turn switch off.

Turn ignition to “OFF,” then to

“START” position.

Contact Buhler Versatile dealer.

Charge indicator lamp stays

on with engine running

Low engine idle speed.

Loose belt.

Malfunctioning battery(ies).

Malfunctioning alternator.

Increase idle speed.

Check automatic belt tensioner.

Check each battery open circuit

voltage for 12.6 volts minimum.

Check electrolyte level and

specific gravity.

Contact Buhler Versatile dealer.