3-36

EVERY 250 HOURS

OPERATION 28

Check the Engine DCA4 Protection Level

The DCA4 protection level must be checked

whenever coolant is added to the cooling system

or whenever the cooling system filter is changed.

Buhler Versatile has a test kit available, part

number FGCC2602, to check the concentration

level. Instructions are included with the test kit.

Contact your Buhler Versatile dealer to obtain

the test kit.

Follow the instructions in the kit to maintain

proper DCA4 protection level.

Figure 3-46

OPERATION 29

Change the Fuel Filter

The fuel filter is located on the left side of the

engine. To replace the fuel filter, 1, unscrew it

from its filter head, 2, and discard the old filter. Fill

the new filter with clean fuel and install it onto the

filter head. Hand tighten the filter 1/2 to 3/4 of a

turn after the seal on top of the filter contacts the

filter head.

IMPORTANT: Discard the used fuel filter

following local laws and regulations.

NOTE: There is no shutoff provided at the

filter head to stop the flow of fuel from the

tanks. The filter head is located high enough

on the engine so that no fuel should escape

when the filter is removed.

Figure 3-47