SECTION 4 - TROUBLESHOOTING

4-11

3-POINT HITCH

PROBLEM

POSSIBLE CAUSE

CORRECTION

Hitch will not raise

Low oil level.

Loose electrical connections.

Blown fuse.

Check and fill hydraulic reservoir.

Check connections at

electrohydraulic valve and

controls.

Replace fuse.

Hitch raises too slowly or

quickly

Rate of raise adjustment

incorrectly set.

Adjust flow control on 3-point

hitch valve section.

Hitch drops too slowly or

quickly

Lowering rate adjustment

incorrectly set.

Adjust rate of lowering flow

control knob.

Hitch overstrokes during

raise or lower and puts the

pump into high pressure

standby

Feedback potentiometer

incorrectly adjusted.

Adjust potentiometer.

BRAKES

PROBLEM

POSSIBLE CAUSE

CORRECTION

Park brake inoperative

Worn brake pads.

Broken park brake cable.

Brake out of adjustment.

Replace brake pads.

Replace broken cable.

Operate park brake lever several

times to automatically adjust

brakes. If no result, contact your

Buhler Versatile dealer.

Pedal bottoms out or feels

mushy

Brake piston seal leaking.

Worn brake pads.

Brake bleeder not sealing.

Leakage in brake valve.

Air in system.

Reservoir level low.

Brakes out of adjustment.

Contact Buhler Versatile dealer.

Replace brake pads.

Tighten bleeder.

Contact Buhler Versatile dealer.

Bleed brake system.

Fill reservoir with proper brake

fluid.

Operate park brake lever several

times to automatically adjust. If no

result, contact Buhler Versatile

dealer.