SECTION 2 - OPERATION

2-105

Caret 1/ Pos. A

Acre accumulator

This displays the acres covered in XXX.X format

based on the implement width and the ground

speed. The display increments as long as the

implement status is down. When the implement

status is up, the acres value stops accumulating

and flashes the value when the acre

accumulator caret is selected.
Caret 2/ Pos. B

Acres per hour

This displays the calculated acres covered per

hour in XXX.X format based on the implement

width and ground speed. This display updates

as long as the implement status is down. When

the implement status is up, the acre per hour

value will display “.0” and an alarm will sound for

3 seconds to indicate that the implement is up.
Caret 3/ Pos. C

Distance Accumulator

(Feet)

This accumulates feet from the radar input in an

XXXX format. To start and stop the distance

accumulator, select a distance accumulator

caret function and press the start/stop touch

switch. To reset the distance accumulator press

and hold the start/stop touch switch until the

LCD blinks and displays “0”. The distance

accumulators (feet and meters) are tied

together, so starting, stopping, or resetting

either distance accumulator does the same

action on the other caret function. The

accumulated

distance

flashes

when

accumulation stops.
Caret 4/ Pos. D

Percent slip

This displays the percentage difference

between the radar input and the sensor input

from the transmission in XXXX format. The slip

caret flashes when the slip is greater than the

slip alarm percentage regardless of what

function is being viewed. When the caret is

flashing, a continuous alarm sounds until the

slip drops below the slip alarm percentage.

While in the alarm condition, other carets can

still selected and viewed; however the slip caret

will continue to flash until the slip drops below

the slip alarm value. The default alarm

percentage is 15%.
Caret 5/ Pos. E

Distance Accumulator

(Meters)

This accumulates meters from the radar in an

XXXX format. To start and stop the distance

accumulator, select a distance accumulator

caret function and press the start/stop touch

switch. To reset the distance accumulator press

and hold the start/stop touch switch until the

LCD blinks and displays “0”. The distance

accumulators (feet and meters) are tied

together, so that starting, stopping, or resetting

either distance accumulator does the same to

the other caret function. The accumulated

distance will flash when accumulation has

stopped.
Caret 6/ Pos. F

Hectares per hour

This displays the calucated hectares covered

per hour in XXX.X format based on the

implement width and ground speed. This

display updates as long as the implement status

is down. When the implement status is up the

hectare per hour value will display “.0” and an

alarm will sound for 3 seconds to indicate that

the implement is up.
Caret 7/ Pos. G

Hectare accumulator

This will display the hectares covered in XXX.X

format based on the implement width and the

current speed in XXX.X format. This display will

increment as long as the implement status is

down. When the implement status is up the

hectares value will stop accumulating and flash

that value when the hectare accumulator caret

is selected.
Slip Alarm
When the percent slip is above the alarm

percent setting a continuous audible alarm

sounds and the slip caret flashes until the

percent slip drops below the alarm value. If the

percent slip caret is selected during an alarm

condition, the current slip value will be displayed

and updated. The maximum value that can be

displayed is 30%.

NOTE: Whether in Percent Slip mode or not,

when the alarm percentage is reached, the TPM

will activate the alarm.
Zeroing Slip Function
To set the zero slip, select the percent slip caret

and drive the tractor at a constant speed in a

zero slip condition then press and hold the reset

touch switch for three seconds until the LCD

blinks.
Acres Accumulator Zeroing Function
To reset the acres accumulators to zero, select

the acres area accumulator and press and hold

the reset touch switch for three seconds until the

LCD blinks and displays “.0”. This resets the

acre area accumulator to zero.