SECTION 3 - LUBRICATION AND MAINTENANCE

3-66

INDICATED BY WARNING LIGHT

Rinse the element with clean, running water.

Rinse from the inside of the element through to

the outside until the water is free of dirt. If a hose

is used, do not exceed 2 bar (30 PSI). A gentle

trickle of water is sufficient and will ensure that

the element is not ruptured.

Shake out excess water from the element and

allow to air dry. DO NOT use compressed air, a

light bulb or heat to dry the element.

NOTE: It usually takes one to three days for a

filter element to dry.

IMPORTANT: Do not attempt to dry the element

with heat or compressed air and do not install

until thoroughly dry as it may rupture. It is

recommended that a new or previously cleaned

element be installed at this service and the

washed element be put aside for installation at

the next service. The spare element should be

stored in a dry place and wrapped to prevent dust

contamination or damage.

When the element is dry, insert a light inside and

check for ruptures. A pinpoint of light indicates a

rupture in the element paper. If this occurs,

replace the element.

Clean the air cleaner body with a lint-free towel

before installing the element.

Inspect the element seal, 1, before installing.

Cracks or chips in the element sealing rubber

indicates a new element must be installed.

Figure 3-105

1

Install the air filter back into the canister. Be sure

the seal on the end of the filter fully contacts the

air cleaner body. The wing nut, 1, has a small

seal on the inner face, and the seal should be in

good condition before the wing nut is tightened. If

the seal is damaged on the wing nut, replace it.