SECTION 1 - GENERAL INFORMATION

1-29

Some monitors require a true ground speed

signal from a radar unit to be fed into them for

proper operation.

Buhler Versatile 4WD tractors equipped with

a Tractor Performance Monitor (TPM) option

can provide this signal to the monitor by

tapping into the existing wire harness on the

tractor.

To tap into the existing signal wire on the

tractor, use the following procedure:

a. Remove the cover from the rear of the

TPM module on the right-hand console.

The cover, 1, is held in position with velcro.

Figure 1-41

b. Pull out wire harness, 1, that is tucked into

the rear of the TPM.

c. The TPM is connected to the main cab wire

harness with a green 8-pin connector.

Locate the gray wire marked “CM-90” that

is plugged into the connector.
Wire “CM-90” is a processed 5-volt signal

that supplies the TPM with a 58.9 Hz/mph

output from the Electronic Instrument

Control System monitor

d. Using a pigtail-type splice connector, tie

into the “CM-90” wire with the wire leading

into the implement monitor.
The monitor will now receive a signal from

the radar unit at the front of the tractor.

e. Route the signal wire along the right-hand

console and out to the implement monitor.

f. Reinstall the TPM wire harness and

connect back into place and install the

TPM backplate.

Figure 1-42

1