SECTION 4 - TROUBLESHOOTING

4-9

PROBLEM

POSSIBLE CAUSE

CORRECTION

Tractor runs for a short time

and shuts off

Automatic shutdown mode

activated.

Partially restricted fuel line.

Check audio and visual indicators

for cause of shutdown. Contact

Buhler Versatile dealer.

Contact Buhler Versatile dealer.

Electronic monitor rotary

select switch failure (“SEL”

“OPEN”)

Open circuit on rotary select

switch for electronic instrument

control system.

Reconnect plug on back of switch.

Replace faulty switch.

Transmission speed sensor

“OPEN” or “SHCR”

Malfunction in sensor or sensor

wiring.

Sensor is unplugged, reconnect.

Sensor wiring is damaged, repair

wiring.

Contact Buhler Versatile dealer.

Engine speed sensor

“OPEN” or “SHCR”

Malfunction in sensor or sensor

wiring.

Sensor is unplugged, reconnect.

Sensor wiring is damaged, repair

wiring.

Contact Buhler Versatile dealer.

Electrical system high/low

voltage

Loose or corroded terminal

connections.

Shorted out electrical system.

Sulfated batteries.

Loose or worn belt.

Clean and tighten connections.

Contact Buhler Versatile dealer.

Check each battery open circuit

voltage for 12.6 volts minimum.

Check electrolyte level and

specific gravity.

Check alternator belt tension.

Replace belt if required.

Batteries will not charge

Loose or corroded terminal

connections.

Sulfated batteries.

Loose or worn belt.

Clean and tighten connections.

Check each battery open circuit

voltage for 12.6 volts minimum.

Check electrolyte level and

specific gravity.

Check alternator belt tension.

Replace belt if required.