SECTION 2 - OPERATION

2-129

The blue, green and tan in cab flow control knobs

are in the right rear corner of the cab and function

identically to the grey flow control.

Figure 2-173

PRESSURE RELEASE DETENT

ADJUSTMENT

The detent adjustment screw, 1, located on the

rear of the valve, may be adjusted to vary the

system pressure required to return each lever to

the neutral position.

To adjust, loosen the jam nut and rotate the

screw clockwise to increase the release detent

pressure. A variable pressure flowmeter should

be used to slowly raise the system pressure to

accurately set each detent. The adjustment

should be made by your authorized Buhler

Versatile dealer.

NOTE: The factory pressure release detent

setting is 15.0 bar (2175 PSI).

WARNING: ONLY ADJUST THE SCREW

WHEN THE REMOTE CONTROL LEVERS

ARE IN NEUTRAL AND THE TRACTOR IS

SHUT OFF.

Figure 2-174

1