SECTION 3 - LUBRICATION AND MAINTENANCE

3-90

AS REQUIRED

Initial Engine Start-up

Initial engine start-up after long periods of

storage can place abnormal loads on the

cranking system. Do not crank the engine

longer than 30 seconds. Allow at least two

minutes between cranking cycles to permit the

starting motor to cool and the batteries to

recover.

IMPORTANT: On initial start of engine, do not

increase speed above 1000 RPM, unless

necessary to prevent stalling, until the engine oil

pressure is normal.

See “Engine Starting” and “Cold-Weather

Starting” in Section 2.

If the engine does not start after 30 seconds,

prime the fuel system using the following

procedure:

Remove the fuel filter and fill it with clean

filtered fuel.

IMPORTANT: Fuel poured directly into the

filter will not be cleaned by the filter and will

go directly into the fuel pump. Be sure that

the fuel is clean.

Remove the suction line from the fuel

injection pump and squirt clean filtered fuel

into the pump.

Start the engine. If the engine still does not

start, consult your Buhler Versatile dealer.