SECTION 4 - TROUBLESHOOTING

4-14

ELECTRONIC INSTRUMENT CONTROL SYSTEM

PROBLEM

POSSIBLE CAUSE

CORRECTION

Lower portion of module

reverts to ground speed

automatically when

monitoring other functions

Tractor moving over 20 km/h

(12.5 MPH).

Normal operation. See Section 2 -

“Normal Operation of the

Electronic Instrument Control

System.”

Lower portion of display

flashes the service interval

one or two indicator

Accrued hours approaching

(within 10 hours) or have reached

preset service interval value.

Normal operation. See Section 2 -

“Normal Operation of the

Electronic Instrument Control

System.”

Upper portion of module

has the words “SET” and

“UP” displayed and system

functions erratically

System is in the calibrate mode.

Turn ignition switch to “OFF”

position and back to “RUN” to

enter the normal operation mode.

Ground speed displayed on

lower portion of module

inaccurate (tractors less

TPM option only)

Values entered into the calibrate

mode are incorrect.

Recalibrate system. See

“Electronic Instrument Control

System” in Section 2.

Values displayed in lower

portion of module are

inaccurate

Units of measure are incorrect

(English or metric).

Recalibrate system. See

“Electronic Instrument Control

System” in Section 2.

Display is blank

Loss of +12V power.

Replace instrumentation fuse.

Contact Buhler Versatile dealer.

Engine Warning Lights (Red

or Yellow) illuminated

Critical (red) or non-critical

(yellow) failure in electronic

engine control circuit.

Contact Buhler Versatile dealer.

Engine Warning Light (red)

illuminated

Engine overspeed.

Reduce engine speed (below

2630 RPM)

Display flashed “EXT ALR”

when turning or at certain

times of the day (TPM

equipped tractors only)

Slip or time of day feature of TPM

reacting.

See TPM in Section 2 of this

manual.