SECTION 5 - SPECIFICATIONS

5-15

ENGINE AIR INTAKE AND EXHAUST

2290

2335

2375

2360

2425

AIR INTAKE
Precleaning

Exhaust Aspirated w/ Precleaner

Air Filter Configuration

Primary (Outer)

Secondary (Inner)

Air Flow - L/S (CFM) @ 2100 RPM

382 (810)

413 (875)

414 (878)

507 (1075)

519 (1100)

EXHAUST OUTLET
MufflerType

Perforated tube and center plug with venturi for intake. Precleaner aspiration.

Air Flow - L/S (CFM) @ 2100 RPM

798 (1690)

873 (1850)

414 (878)

1132 (2400)

1261 (2675)

FUEL SYSTEM

2290

2335

2375

2360

2425

Fuel Tanks:
Total Capacity - L (gal.)

927 (245)

Usable Capacity - L (gal.)

871 (230)

Vented

Both Tanks

Fuel Filter

Single Element

Cold Start

Measured 4.8 cc shot of fluid at each switch activation.

Thermoguard protected above 27°C (81°F)

Fuel Flow

Drawn from left tank, passes through the engine fuel system. Return fuel goes

through the fuel cooler back to the right tank. Crossover pipe between the two

tanks. Separate fill spout and drain on each tank.

COOLING SYSTEM

2290

2335

2375

2360

2425

Coolant capacity - L (gal.)

59 (15.6)

60 (15.9)

60 (15.9)

Radiator Core Size (LxW) - mm (in.)

978 x 894 (38.5 x 35.2)

Fins per Inch

9

Number of Rows

6

6

7

6

7

Fan Diameter - mm (in.) x Blade

Pitch Width - mm (in.)

813 (32)

x 89 (3.5)

838 (33)

x 89 (3.5)

813 (32)

x 89 (3.5)

838 (33)

x 89 (3.5)

Number of Blades

8

Pressure Cap Setting - kPa (PSI)

97 (14)

Thermostat Opens

82°C (180°F)

Thermostat Full Open

93°C (200°F)

Type of System

Pressurized recirculating full flow bypass with filter and corrosion inhibitor.

Advertising