SECTION 3 - LUBRICATION AND MAINTENANCE

3-60

EVERY 1500 HOURS OR YEARLY

Check the front mounts, 1, for wear or

deterioration and torque the mount bolts and

nuts to 280 N⋅m (205 ft. lbs.). Torque the

mounting bracket to engine bolts, 2, to 45 N⋅m

(35 ft. lbs.).

Figure 3-96

1

2

OPERATION 57

Check the Engine Turbocharger

Connections
On the Model 2290, 2335 and 2375 (QSM11),

check the exhaust pipe to turbo outlet clamp, 1.

Torque the clamp to 9 N⋅m (80 in. lbs.). Torque

the lower oil drain line cap screws, 2, to 27 N⋅m

(239 in. lbs.). Tighten the upper oil supply line

fitting, 3. 20 N m (177 in. lbs.)
Tighten the four nuts that mount the turbocharger

to the exhaust manifold of the engine to 61 N⋅m

(45 ft. lbs.).

Figure 3-97

1

2

3

Advertising