SECTION 4 - TROUBLESHOOTING

4-13

TRACTOR PERFORMANCE MONITOR

PROBLEM

POSSIBLE CAUSE

CORRECTION

Display blank

Loss of +12 VDC power

Replace fuse for TPM (3-amp

instrumentation fuse).

“Err” displayed

Recent loss of +12 VDC power

Selected function is detected to

contain an invalid number

Reprogram the time of day

function.

Reprogram the indicated function.

No AREA accumulation or

AREA/HR prediction

Incorrect installation of implement

status switch

Implement status switch input

inhibited due to broken or

damaged cable or because

implement status switch is

defective

Turn tractor ignition switch to ON,

performance monitor should

power-up. Press RESET (AREA)

switch, with AREA displayed; if

UP message was displayed, it

should clear. The UP message

should alternate on and off each

time the switch is pressed. If so,

check installation of the

implement status switch. Be sure

the trip spring to implement status

switch is correctly stretched. If no

implement status switch is being

used, be sure the “UP” indicator

does not show on the display.

Visually inspect the implement

status switch cable for damage. If

damage is found, replace the

cable.

No wheel slip indication

No axle speed input

No radar speed input

Use the electronic instrument

cluster to check out the operation

of the transmission output speed

sensor. If the dash will not

indicate a ground speed, contact

your Buhler Versatile dealer.

Use the distance measuring

feature of the performance

monitor to determine if the radar

is functioning. If not, contact your

Buhler Versatile dealer.