SECTION 2 - OPERATION

2-90

Electronic Monitor Rotary Select Switch

Failures

The Electronic Instrument Control System will

notify the operator that the rotary select switch

has an open circuit. The select switch will not

function in any of the calibration modes or normal

operation

positions.

Refer

to

“Electrical

Troubleshooting” in Section 4 for possible

causes of an open circuit. The following

description details the reaction of the electronic

monitor in the event of an open circuit on the

rotary select switch:

With the ignition in the “RUN” position and an

open circuit detected on the rotary select switch,

the lower portion of the monitor will flash “SEL”

and “OPEN.” No audible alarm will sound.

Pressing the acknowledge/reset button will not

clear the “SEL” “OPEN” display. The upper

portion of the monitor will continue to show

engine RPM. The “SEL” “OPEN” display will be

activated in any position of the rotary select

switch if an open circuit is detected.

Figure 2-121